Digital Probe Library

One probe library,
every QC digital recorder.

Fourteen interchangeable digital probes and 4–20 mA transmitters that cover the parameters every regulated facility monitors — temperature from −200 °C cryo to +700 °C industrial, humidity, CO₂, O₂, differential pressure, and light. Calibration coefficients live on the probe itself, so a sensor swap is never a re-validation.

14SKUs Digital probes & transmitters
−200to +700 °C Total temperature span
3recorders Nova · Nano · LoRa SPY Digital
Digital Sensor — stainless sensing tip on coiled cable terminating in a teal twist-lock connector
Vaccine fridge · V‑03 4.62°C In spec · live
Calibration coefficients stored on probeSwap without revalidation
System Architecture

Probe → Recorder → MySirius. Traceable end-to-end.

A Digital Sensor stores its own calibration coefficients in onboard memory. The recorder reads them on connection, applies them in firmware, and ships the corrected reading to MySirius — every record stamped with the probe serial that produced it.

PROBE · cal stored Digital TH probe — green vented body with calibration coefficients stored on the probe
Stage 01 · Sense

Digital Probe

Digital Sensors and probes carry their own calibration coefficients onboard. Swap a probe between recorders and the calibration travels with it.

8 probe types · 1 connector
2nd-degree error model on probe
DATA LOGGING RECORDER Nova SPY Digital recorder reading a connected digital probe
Stage 02 · Record

SPY Digital Recorder

Nova, Nano, or LoRa SPY Digital reads the probe's coefficients on connect, applies them in firmware, and broadcasts the corrected value over the QC network.

3 recorders · same protocol
Hot-swap mid-monitoring
MySirius LIVE
−80 ULT · F‑14 OK
−79.4°C
Probe sn 13984-A402 · cal 2026‑02‑11
CO₂ incubator · I‑02 SWAP
5.02% CO₂
Probe 12365 hot-swapped 09:14 · auto-cal applied
ΔP · cleanroom 4 OK
+12Pa
Probe sn 11185‑B017 · 4–20 mA
Stage 03 · Record & Sign

MySirius

Each measurement is stamped with the probe serial and the coefficient set in force at the time — every record reconstructable on audit, even years after a probe was swapped.

21 CFR Part 11 · GMP · GxP
ALCOA+ data integrity
14
Probes & transmitters
8 digital probes · 6 4–20 mA transmitters
±0.20°C
Standard accuracy
Digital Sensor T° from −40 to +50 °C
≤0.1°C / yr
Drift after one year
Documented metrological stability
EN 15140
Mapping standard
Reference probes meet response-time spec
The Digital Probe Catalog

Eight probes, six transmitters, one signal chain.

Two families share a digital backbone: Digital Sensors (cal-on-probe, plug into any SPY Digital recorder) and 4–20 mA transmitters (wall-mount, gas / pressure / light, connect through a Nano SPY U or LoRa SPY U).

14 Sensors in the library −200 °C to +700 °C · CO₂ · O₂ · ΔP · LUX All compatible with MySirius

Group 01 Digital Sensors

Direct-plug digital probes — calibration coefficients written into onboard memory, swap traceable mid-mission.

Temperature Compact Cold-chain logistics
PN 13912 Short digital temperature probe — Ø7 × 25 mm stainless body with serialised calibration label

Digital Sensor T° ShortCompact temperature probe

Same digital protocol as the standard T°, in a short-shaft body for tight fittings and faster response.

Range−40 to +80 °C
Accuracy±0.20 °C
(−40…+50 °C)
ShaftCompact stainless
ProtectionIP 68 (probe)
Tight fittings Fast response
Cryo · ULT
PN 13984 Digital low-temperature probe — coiled black PFA cable with green sensing tip

Digital Sensor Low TemperatureUltra-low temperature probe

Built for the cold chain extreme — down to −200 °C for ULT freezers, LN₂ tanks and cryoconservation.

Range−200 to 0 °C
Sensor typeDigital low-T
Cable3 m Teflon
ProtectionIP 68 (probe)
ULT freezers LN₂ tanks Cryoconservation
Temp + RH
PN 12347 Digital TH probe — green vented body housing the temperature and humidity element

Digital Sensor THTemperature & humidity probe

One digital cable, two channels — temperature and relative humidity through a single connector.

Range T°−30 to +70 °C
Range RH0–100 % RH
TipVented mesh
ProtectionIP 65 (tip)
Warehouses Stability chambers GMP rooms
Reference · PT100
PN 13947 Digital temperature reference probe — PT100 element on coiled cable with teal connector

Digital Sensor ReferenceHigh-precision PT100 reference probe

For mapping campaigns and on-site validation — PT100 reference accuracy with EN 15140 response time.

Range−50 to +180 °C
ElementPT100, Ø2.2 × 35 mm
StandardEN 15140 mapping
Cable3 m PFA
Mapping On-site validation COFRAC pts
Reference · PT100 Compact
PN 14129 Short digital reference probe — compact green head with fast-response stainless stem

Short Digital Sensor ReferenceCompact reference probe

A reference-grade probe in a fast-response, short-shaft body — slips into smaller chambers and small-volume containers.

Range−40 to +80 °C
ElementPT100 compact
ResponseFast (EN 15140)
CablePFA · short
Small chambers Vials & vials racks
Bench standard
PN 13947 SPRT calibration-bench temperature sensor on coiled cable

Digital Sensor StandardProfessional calibration-bench probe

For the metrology lab — −196 °C to +180 °C full span for cross-calibration of recorders, other probes and third-party hardware.

Range−196 to +180 °C
UseReference standard
Resolution0.001 °C
CablePFA
Metrology lab Cross-cal
High temperature Industrial
PN 13264 PT100 high-temperature probe — long stainless stem with insulated handle

PT100 High Temperature ProbeIndustrial & pharmaceutical

Built for autoclaves, ovens and sterilization tunnels — up to +700 °C through a hardened cable gland and ceramic head.

Range−50 to +700 °C
ElementPT100 · class A
HeadIndustrial
ProtectionIP 65 head
Autoclaves Ovens Sterilization

Group 02 Transmitters

Wall-mount 4–20 mA front-ends for the parameters a probe alone can't capture — gas, light and differential pressure. Connect through a Nano SPY U or LoRa SPY U.

TH transmitter Ambient
PN 12367 Precision TH probe — vented stainless filter over the temperature and humidity element

Ambient TH Precision TransmitterWall-mount T° + RH

For HVAC, food and pharmaceutical rooms — temperature and humidity in a single wall-mount unit with a local display.

Range T°−40 to +60 °C
Range RH0–100 % RH
Output4–20 mA
MountWall, IP 54
HVAC GMP rooms Food cGMP
Industrial TH
PN 12366 Industrial TH probe — stainless sintered filter on armoured cable

Industrial Precision TH TransmitterRemote-probe TH for harsh environments

A wall transmitter with a remote stainless probe on armored cable — −100 to +200 °C for steam tunnels, dryers and process loops.

Range T°−100 to +200 °C
Range RH0–100 % RH
Output4–20 mA
ProbeRemote stainless
Process loops Dryers Steam tunnels
CO₂ · NDIR
PN 12365 CO₂ probe — white NDIR sensor cylinder with threaded connector

CO₂ Transmitter0–20% CO₂ NDIR

Made for the CO₂ incubator — NDIR optical measurement 0–20 %, drift-stable for long missions.

Range0–20 % CO₂
PrincipleNDIR optical
Output4–20 mA
MountWall, IP 54
CO₂ incubators Cell culture
O₂ · electrochemical
PN 09491 Air check O₂ transmitter with local oxygen display

O₂ Transmitter0–25% oxygen volume

For LN₂ storage rooms and cryoconservation cells — oxygen displacement alarm as a life-safety layer.

Range0–25 % O₂
PrincipleElectrochemical
Output4–20 mA
Use caseLife safety
LN₂ rooms Cryoconservation Storage areas
ΔP · cleanroom
PN 11185 Differential pressure transmitter in clear housing with pressure ports

ΔP TransmitterDifferential pressure for clean rooms

Cleanroom cascades, isolators and BSCs — 30 / 50 / 100 Pa ranges, <20 ms response, 4–20 mA out.

Range30 / 50 / 100 Pa
Accuracy±1 % EM
Response< 20 ms
Output4–20 mA
Cleanrooms Isolators BSCs
Lux
PN 09588 kLux light-intensity sensor — stainless housing with cosine-corrected diffuser dome

Lux TransmitterLight intensity measurement

A cosine-corrected light sensor for storage areas, inspection booths and stability chambers — photometric lux output, 4–20 mA.

RangeLux (photometric)
SensorCosine-corrected
Output4–20 mA
MountWall, indoor
Stability chambers Inspection booths Storage areas
Compatible recorders

One probe protocol.
Three data recorders.

Every Digital Sensor and PT100 probe in the catalog plugs into any of the three SPY Digital recorders. Pick the recorder for the form factor — the probe stays the same, and so does the calibration history.

A question worth asking
When a probe gets recalibrated mid-mission, can your monitoring history prove which coefficient set produced each historical record?
Run Your REM Risk Assessment
Cross-Platform

One library — three deployment options.

The digital probes are the same on every SPY Digital recorder. The choice between Nova, Nano and LoRa is about form factor and range. Compare side-by-side before you spec a fleet.

Compare LoRa · Nano · Nova
LoRa SPY wireless transmitter
LoRa®
Long-range wireless
Nano SPY sensor
Nano
1 s measurement
Probe hot-swap
Nova SPY in-chamber recorder
Nova
In-chamber recorder
Built-in opening sensor
Digital temperature probe
Probes
Common to all three